Skip to product information
1 of 1

GeneBio Systems

Testo CLIA kit (General species)

Testo CLIA kit (General species)

SKU:CCA458Ge

Regular price $1,713.60 CAD
Regular price Sale price $1,713.60 CAD
Sale Sold out
Shipping calculated at checkout.

Size: 96Tests

# of Times Cited in literature: -

Prepare Time: 2-7 days(please inquire for mutiple units)

Target Name: Testo

Target Full Name: Testosterone

Alternative Names: T; Testesteron; Testeronun

Target Species: General species

Uniprot: -

Gene ID: -

Featured Series: CE kit

Featured Series Function: Detects small molecule

Specificity: Reactive with General species Testo / Testosterone

Method: Chemiluminescence

Detection principle: Competitive Inhibition

Detection range: 117.2-30,000pg/mL

Sensitivity: 40.5pg/mL

Assay Time: 2h

Sample Size: 50uL

Recommended/Predicted Sample Types: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Testosterone (Testo) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Testosterone (Testo) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Testosterone (Testo). No significant cross-reactivity or interference between Testosterone (Testo) and analogues was observed.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 50µL standard or sample to each well. And then add 50µL prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37°C; 3. Aspirate and wash 3 times; 4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 5. Aspirate and wash 5 times; 6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C; 7. Read RLU value immediately.

Test principle: The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Testosterone (Testo). A competitive inhibition reaction is launched between biotin labeled Testosterone (Testo) and unlabeled Testosterone (Testo) (Standards or samples) with the pre-coated antibody specific to Testosterone (Testo). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Testosterone (Testo) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Testosterone (Testo) level in the sample or standard.

Research Area: Endocrinology;Reproductive science;Hormone metabolism;

References Citing This Product: Growth differential factor-9 inhibits testosterone production in mouse theca interstitial cells