Skip to product information
1 of 1

GeneBio Systems

OCT4 ELISA kit (Human)

OCT4 ELISA kit (Human)

SKU:SEA424Hu

Regular price $1,323.00 CAD
Regular price Sale price $1,323.00 CAD
Sale Sold out
Shipping calculated at checkout.

Size: 96Tests

# of Times Cited in literature: 1

Prepare Time: 2-7 days(please inquire for mutiple units)

Target Name: OCT4

Target Full Name: Octamer Binding Transcription Factor 4

Alternative Names: POU5F1; OCT3; OTF3; OTF4; Octamer-4; POU Domain Class 5 Transcription Factor 1; POU Class 5 Homoeobox 1; Octamer-binding protein 3

Target Species: Human

Uniprot: Q01860

Gene ID: 5460

Featured Series: SE kit

Featured Series Function: Detects protein (regular version)

Specificity: Reactive with Human OCT4 / Octamer Binding Transcription Factor 4

Method: Colormetric

Detection principle: Double-antibody Sandwich

Detection range: 0.156-10ng/mL

Sensitivity: 0.057ng/mL

Assay Time: 3h

Sample Size: 100uL

Recommended/Predicted Sample Types: Tissue Homogenates, Cell Lysates and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Octamer Binding Transcription Factor 4 (OCT4) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Octamer Binding Transcription Factor 4 (OCT4) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Octamer Binding Transcription Factor 4 (OCT4). No significant cross-reactivity or interference between Octamer Binding Transcription Factor 4 (OCT4) and analogues was observed.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Octamer Binding Transcription Factor 4 (OCT4). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Octamer Binding Transcription Factor 4 (OCT4). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Octamer Binding Transcription Factor 4 (OCT4), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Octamer Binding Transcription Factor 4 (OCT4) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Research Area: Signal transduction;Developmental science;

References Citing This Product: A universal glucometer-based biosensor for portable and quantitative detection of transcription factors

Upregulation of stem cell markers ALDH1A1 and OCT4 as potential biomarkers for the early detection of cervical carcinoma

View full details