GeneBio Systems
OCLN ELISA kit (Human)
OCLN ELISA kit (Human)
SKU:SEC228Hu
Couldn't load pickup availability
Size: 96Tests
# of Times Cited in literature: 9
Prepare Time: 1-3 days(please inquire for mutiple units)
Target Name: OCLN
Target Full Name: Occludin
Alternative Names: Tight Junction Protein Occludin TM4 Minus
Target Species: Human
Uniprot: Q16625
Gene ID: 100506658
Featured Series: SE kit
Featured Series Function: Detects protein (regular version)
Specificity: Reactive with Human OCLN / Occludin
Method: Colormetric
Detection principle: Double-antibody Sandwich
Detection range: 0.156-10ng/mL
Sensitivity: 0.059ng/mL
Assay Time: 3h
Sample Size: 100uL
Recommended/Predicted Sample Types: Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Occludin (OCLN) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Occludin (OCLN) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Shelf-life: 12 months
Specificity: This assay has high sensitivity and excellent specificity for detection of Occludin (OCLN). No significant cross-reactivity or interference between Occludin (OCLN) and analogues was observed.
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Occludin (OCLN). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Occludin (OCLN). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Occludin (OCLN), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Occludin (OCLN) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Research Area: Signal transduction;
References Citing This Product: HIV-1 Tat protein increases the permeability of brain endothelial cells by both inhibiting occludin expression and cleaving occludin via matrix metalloproteinase-9
A new panel of blood biomarkers for the diagnosis of mild traumatic brain injury/concussion in adults
Methods for Diagnosis and Treatment of Concussion or Brain Injury
The Effect of Dietary Quercetin on the Glutathione Redox System and Small Intestinal Functionality of Weaned Piglets
Peripheral blood occludin level as a biomarker for preoperative cerebral edema in patients with brain tumors
Intestinal Permeability in Participants With Thermal Injury: A Case Series From a Prospective, Longitudinal Study (HESTIA)
A comparison of the effects of monotherapy with rosuvastatin, atorvastatin or ezetimibe versus combination treatment with rosuvastatin-ezetimibe and …
Higher serum occludin after successful reperfusion Is associated with early neurological deterioration
Impact de l'incorporation d'acides gras à chaine moyenne, de suppléments de levures et d'avoine nue sur la santé intestinale ainsi que sur la consommation …
