Skip to product information
1 of 1

GeneBio Systems

NGF CLIA kit (Rat)

NGF CLIA kit (Rat)

SKU:SCA105Ra

Regular price $1,915.20 CAD
Regular price Sale price $1,915.20 CAD
Sale Sold out
Shipping calculated at checkout.

Size: 96Tests

# of Times Cited in literature: -

Prepare Time: 2-7 days(please inquire for mutiple units)

Target Name: NGF

Target Full Name: Nerve Growth Factor

Alternative Names: NGFB; Beta-NGF; HSAN5; NGF-B; Beta-Nerve Growth Factor

Target Species: Rat

Uniprot: P25427

Gene ID: 310738

Featured Series: SE kit

Featured Series Function: Detects protein (regular version)

Specificity: Reactive with Rat NGF / Nerve Growth Factor

Method: Chemiluminescence

Detection principle: Double-antibody Sandwich

Detection range: 8.23-6,000pg/mL

Sensitivity: 3.13pg/mL

Assay Time: 2h, 40min

Sample Size: 100uL

Recommended/Predicted Sample Types: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nerve Growth Factor (NGF) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nerve Growth Factor (NGF) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Nerve Growth Factor (NGF). No significant cross-reactivity or interference between Nerve Growth Factor (NGF) and analogues was observed.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C; 8. Read RLU value immediately.

Test principle: The microplate provided in this kit has been pre-coated with an antibody specific to Nerve Growth Factor (NGF). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Nerve Growth Factor (NGF). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Nerve Growth Factor (NGF) level in the sample or standard.;

Research Area: Cytokine;Neuro science;

References Citing This Product: High glucose upregulates CYP24A1 expression which attenuates the ability of 1,25(OH)2D3