GeneBio Systems
Anti-SLC30A8 ELISA kit (Human)
Anti-SLC30A8 ELISA kit (Human)
SKU:AEE490Hu
Couldn't load pickup availability
Size: 96Tests
# of Times Cited in literature: 1
Prepare Time: 2-7 days(please inquire for mutiple units)
Target Name: SLC30A8
Target Full Name: Solute Carrier Family 30 Member 8
Alternative Names: ZNT8; Zinc Transporter 8
Target Species: Human
Uniprot: Q8IWU4
Gene ID: 169026
Featured Series: AE kit
Featured Series Function: Detects protein (antigen)
Specificity: Reactive with Human SLC30A8 / Solute Carrier Family 30 Member 8
Method: Colormetric
Detection principle: Competitive Inhibition
Detection range: 3.12-200ng/mL
Sensitivity: 1.27ng/mL
Assay Time: 2h, 30min
Sample Size: 50uL
Recommended/Predicted Sample Types: Serum, Plasma, Tissue Homogenatesand Other Biological Fluids
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Solute Carrier Family 30 Member 8 Antibody (Anti-SLC30A8) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Solute Carrier Family 30 Member 8 Antibody (Anti-SLC30A8) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Shelf-life: 12 months
Specificity: This assay has high sensitivity and excellent specificity for detection of Anti-Solute Carrier Family 30 Member 8 Antibody (Anti-SLC30A8). No significant cross-reactivity or interference between Anti-Solute Carrier Family 30 Member 8 Antibody (Anti-SLC30A8) and analogues was observed.
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 5 times; 5. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 6. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle: The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Anti-Solute Carrier Family 30 Member 8 Antibody (Anti-SLC30A8) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Anti-Solute Carrier Family 30 Member 8 Antibody (Anti-SLC30A8) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Research Area: Signal transduction;
References Citing This Product: -