GeneBio Systems
Anti-ACE2 ELISA kit (Human)
Anti-ACE2 ELISA kit (Human)
SKU:AEB886Hu
Couldn't load pickup availability
Size: 96Tests
# of Times Cited in literature: -
Prepare Time: 2-7 days(please inquire for mutiple units)
Target Name: ACE2
Target Full Name: Angiotensin I Converting Enzyme 2
Alternative Names: ACEH; ACEII; ACE-II; Peptidyl-Dipeptidase A; ACE-related carboxypeptidase; Angiotensin-converting enzyme homolog; Metalloprotease MPROT15
Target Species: Human
Uniprot: Q9BYF1
Gene ID: 59272
Featured Series: AE kit
Featured Series Function: Detects protein (antigen)
Specificity: Reactive with Human ACE2 / Angiotensin I Converting Enzyme 2
Method: Colormetric
Detection principle: Competitive Inhibition
Detection range: 3.12-200ng/mL
Sensitivity: 1.15ng/mL
Assay Time: 2h, 30min
Sample Size: 50uL
Recommended/Predicted Sample Types: Serum, Plasma and other Biological Fluids
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Angiotensin I Converting Enzyme 2 Antibody (Anti-ACE2) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Angiotensin I Converting Enzyme 2 Antibody (Anti-ACE2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Shelf-life: 12 months
Specificity: This assay has high sensitivity and excellent specificity for detection of Anti-Angiotensin I Converting Enzyme 2 Antibody (Anti-ACE2). No significant cross-reactivity or interference between Anti-Angiotensin I Converting Enzyme 2 Antibody (Anti-ACE2) and analogues was observed.
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 5 times; 5. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 6. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle: The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Anti-Angiotensin I Converting Enzyme 2 Antibody (Anti-ACE2) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Anti-Angiotensin I Converting Enzyme 2 Antibody (Anti-ACE2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Research Area: Enzyme & Kinase;Metabolic pathway;Endocrinology;Cardiovascular biology;Neuro science;Hepatology;
References Citing This Product: -