Ret ELISA kit (General species)

Ret ELISA kit (General species)

SKU:CED051Ge

Regular price ¥214,600 JPY
Regular price Sale price ¥214,600 JPY
Sale Sold out
Shipping calculated at checkout.

Size: 96Tests

# of Times Cited in literature: 7

Prepare Time: 1-3 days(please inquire for mutiple units)

Target Name: Ret

Target Full Name: Retinol

Alternative Names: VA; Vitamin A; Aquasola

Target Species: General species

Uniprot: -

Gene ID: -

Featured Series: CE kit

Featured Series Function: Detects small molecule

Specificity: Reactive with General species Ret / Retinol

Method: Colormetric

Detection principle: Competitive Inhibition

Detection range: 123.5-10,000ng/mL

Sensitivity: 45.1ng/mL

Assay Time: 2h

Sample Size: 50uL

Recommended/Predicted Sample Types: Serum, Plasma and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Retinol (Ret) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Retinol (Ret) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Retinol (Ret). No significant cross-reactivity or interference between Retinol (Ret) and analogues was observed.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 50µL standard or sample to each well. And then add 50µL prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37°C; 3. Aspirate and wash 3 times; 4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 5. Aspirate and wash 5 times; 6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 7. Add 50µL Stop Solution. Read at 450 nm immediately.

Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Retinol (Ret) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Retinol (Ret) and unlabeled Retinol (Ret) (Standards or samples) with the pre-coated antibody specific to Retinol (Ret). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Retinol (Ret) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Retinol (Ret) in the sample.

Research Area: -

References Citing This Product: Effects of Vitamin A Overdose on the Immune system in rats

Salivary 1, 5-Anhydroglucitol and Vitamin Levels in Relation to Caries Risk in Children

Oxidative stress indicators in Chinese women with PCOS and correlation with features of metabolic syndrome and dependency on lipid patterns

Prooxidant effect of α-tocopherol in pancreatic tumors.

Vitamin A, C, D, E and B12 Levels in Leprosy: A Case Control Study

Protocol: Prevalence of specific micronutrient deficiencies in urban school going children of India aged between 6 and 16 years: study protocol for a …

Prevalence of specific micronutrient deficiencies in urban school going children and adolescence of India: A multicenter cross-sectional study

Retinol Depletion in COVID-19

View full details