PF4 ELISA kit (Human)

PF4 ELISA kit (Human)

SKU:SEA172Hu

Regular price ¥147,300 JPY
Regular price Sale price ¥147,300 JPY
Sale Sold out
Shipping calculated at checkout.

Size: 96Tests

# of Times Cited in literature: 9

Prepare Time: 1-3 days(please inquire for mutiple units)

Target Name: PF4

Target Full Name: Platelet Factor 4

Alternative Names: CXCL4; SCYB4; Chemokine C-X-C-Motif Ligand 4; Oncostatin-A; Iroplact

Target Species: Human

Uniprot: P02776

Gene ID: 5196

Featured Series: SE kit

Featured Series Function: Detects protein (regular version)

Specificity: Reactive with Human PF4 / Platelet Factor 4

Method: Colormetric

Detection principle: Double-antibody Sandwich

Detection range: 1.56-100pg/mL

Sensitivity: 0.65pg/mL

Assay Time: 3h

Sample Size: 100uL

Recommended/Predicted Sample Types: Serum, Platelet-Poor Plasma and Cell Culture Supernates

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Platelet Factor 4 (PF4) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Platelet Factor 4 (PF4) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Platelet Factor 4 (PF4). No significant cross-reactivity or interference between Platelet Factor 4 (PF4) and analogues was observed.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Platelet Factor 4 (PF4). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Platelet Factor 4 (PF4). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Platelet Factor 4 (PF4), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Platelet Factor 4 (PF4) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Research Area: Cytokine;Hematology;

References Citing This Product: Secretome of apoptotic peripheral blood cells (APOSEC) attenuates microvascular obstruction in a porcine closed chest reperfused acute myocardial infarction model: role of platelet aggregation and vasodilation

Short and long-term changes in platelet and inflammatory biomarkers after cryoballoon and radiofrequency ablation

Data for short and long-term prothrombotic biomarkers after cryoballoon and radiofrequency ablation

Evaluating Platelet Activation Related to the Degradation of Biomaterials Using Molecular Markers

View full details