Skip to product information
1 of 1

GeneBio Systems

eNOS ELISA kit (Human)

eNOS ELISA kit (Human)

SKU:SEA868Hu

Regular price ¥165,700 JPY
Regular price Sale price ¥165,700 JPY
Sale Sold out
Shipping calculated at checkout.

Size: 96Tests

# of Times Cited in literature: 19

Prepare Time: 1-3 days(please inquire for mutiple units)

Target Name: eNOS

Target Full Name: Endothelial NOS

Alternative Names: NOS3; ECNOS; NOS III; E-NOS; C-NOS; ENOS; CNOS; Constitutive NOS; Nitric Oxide Synthase 3, Endothelial

Target Species: Human

Uniprot: P29474

Gene ID: 4846

Featured Series: SE kit

Featured Series Function: Detects protein (regular version)

Specificity: Reactive with Human eNOS / Endothelial NOS

Method: Colormetric

Detection principle: Double-antibody Sandwich

Detection range: 0.156-10ng/mL

Sensitivity: 0.057ng/mL

Assay Time: 3h

Sample Size: 100uL

Recommended/Predicted Sample Types: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Endothelial NOS (eNOS) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Endothelial NOS (eNOS) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Endothelial NOS (eNOS). No significant cross-reactivity or interference between Endothelial NOS (eNOS) and analogues was observed.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Endothelial NOS (eNOS). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Endothelial NOS (eNOS). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Endothelial NOS (eNOS), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Endothelial NOS (eNOS) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Research Area: Enzyme & Kinase;Cardiovascular biology;

References Citing This Product: Inflammation influence on the formation of endothelial dysfunction in hypertensive patients caused by obesity

SIRT1 Gene Polymorphisms Affect the Protein Expression in Cardiovascular Diseases

Soluble Lectin-Like Oxidized LDL Receptor 1 as a Possible Mediator of Endothelial Dysfunction in Patients With Metabolic Syndrome

Chemerin plays a protective role by regulating human umbilical vein endothelial cell-induced nitric oxide signaling in preeclampsia

A Remarkable Age-Related Increase in SIRT1 Protein Expression against Oxidative Stress in Elderly:

Mutant DD genotype of NFKB1 gene is associated with the susceptibility and severity of coronary artery disease.

ThE REmOdELINg Of LEfT ATRIUm ANd vAsOdILATION fAcTORs
View full details