Skip to product information
1 of 1

GeneBio Systems

CXCL7 ELISA kit (Human)

CXCL7 ELISA kit (Human)

SKU:SEA370Hu

Regular price ¥165,700 JPY
Regular price Sale price ¥165,700 JPY
Sale Sold out
Shipping calculated at checkout.

Size: 96Tests

# of Times Cited in literature: 11

Prepare Time: 1-3 days(please inquire for mutiple units)

Target Name: CXCL7

Target Full Name: Chemokine (C-X-C motif) ligand 7

Alternative Names: CXCL7; PPBP; PBP; B-TG1; CTAP-III; CTAP3; CTAPIII; LA-PF4; LDGF; MDGF; NAP2; SCYB7; TC1; TC2; TGB1; THBGB1; Pro-Platelet Basic Protein; Beta-Thromboglobulin

Target Species: Human

Uniprot: P02775

Gene ID: 5473

Featured Series: SE kit

Featured Series Function: Detects protein (regular version)

Specificity: Reactive with Human CXCL7 / Chemokine (C-X-C motif) ligand 7

Method: Colormetric

Detection principle: Double-antibody Sandwich

Detection range: 15.6-1,000pg/mL

Sensitivity: 6.9pg/mL

Assay Time: 3h

Sample Size: 100uL

Recommended/Predicted Sample Types: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine (C-X-C motif) ligand 7 ( CXCL7) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine (C-X-C motif) ligand 7 ( CXCL7) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Chemokine (C-X-C motif) ligand 7 ( CXCL7). No significant cross-reactivity or interference between Chemokine (C-X-C motif) ligand 7 ( CXCL7) and analogues was observed.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Chemokine (C-X-C motif) ligand 7 ( CXCL7). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Chemokine (C-X-C motif) ligand 7 ( CXCL7). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Chemokine (C-X-C motif) ligand 7 ( CXCL7), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Chemokine (C-X-C motif) ligand 7 ( CXCL7) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Research Area: Cytokine;Hematology;

References Citing This Product: Strict heart rate control attenuates prothrombotic state and platelet activity in patients with non-valvular permanent atrial fibrillation.

STUDIES ON THE STORAGE OF POOLED PLATELETS IN NON DOP PVC CONTAINERS

Bioprofiling of platelets in medicated patients with depression.

Ex vivo simulation of cardiopulmonary bypass with human blood for hemocompatibility testing

Differential changes in platelet reactivity induced by acute physical compared to persistent mental stress