Skip to product information
1 of 1

GeneBio Systems

ALD CLIA kit (General species)

ALD CLIA kit (General species)

SKU:CCA911Ge

Regular price ¥251,100 JPY
Regular price Sale price ¥251,100 JPY
Sale Sold out
Shipping calculated at checkout.

Size: 96Tests

# of Times Cited in literature: -

Prepare Time: 2-7 days(please inquire for mutiple units)

Target Name: ALD

Target Full Name: Aldosterone

Alternative Names: -

Target Species: General species

Uniprot: -

Gene ID: -

Featured Series: CE kit

Featured Series Function: Detects small molecule

Specificity: Reactive with General species ALD / Aldosterone

Method: Chemiluminescence

Detection principle: Competitive Inhibition

Detection range: 7.81-2,000pg/mL

Sensitivity: 2.93pg/mL

Assay Time: 2h

Sample Size: 50uL

Recommended/Predicted Sample Types: Serum, Plasma and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Aldosterone (ALD) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Aldosterone (ALD) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Aldosterone (ALD). No significant cross-reactivity or interference between Aldosterone (ALD) and analogues was observed.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 50µL standard or sample to each well. And then add 50µL prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37°C; 3. Aspirate and wash 3 times; 4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 5. Aspirate and wash 5 times; 6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C; 7. Read RLU value immediately.

Test principle: The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Aldosterone (ALD). A competitive inhibition reaction is launched between biotin labeled Aldosterone (ALD) and unlabeled Aldosterone (ALD) (Standards or samples) with the pre-coated antibody specific to Aldosterone (ALD). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Aldosterone (ALD) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Aldosterone (ALD) level in the sample or standard.

Research Area: Metabolic pathway;Endocrinology;Hormone metabolism;

References Citing This Product: -