GeneBio Systems
MMP9 CLIA kit (Human)
MMP9 CLIA kit (Human)
SKU:SCA553Hu
Couldn't load pickup availability
Size: 96Tests
# of Times Cited in literature: 1
Prepare Time: 2-7 days(please inquire for mutiple units)
Target Name: MMP9
Target Full Name: Matrix Metalloproteinase 9
Alternative Names: GELB; Gelatinase B; CLG4B; CLG4-B; 92 KDa Gelatinase; 92kDa Type IV Collagenase
Target Species: Human
Uniprot: P14780
Gene ID: 4318
Featured Series: SE kit
Featured Series Function: Detects protein (regular version)
Specificity: Reactive with Human MMP9 / Matrix Metalloproteinase 9
Method: Chemiluminescence
Detection principle: Double-antibody Sandwich
Detection range: 41.2-30,000pg/mL
Sensitivity: 15.7pg/mL
Assay Time: 2h, 40min
Sample Size: 100uL
Recommended/Predicted Sample Types: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Matrix Metalloproteinase 9 (MMP9) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Matrix Metalloproteinase 9 (MMP9) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Shelf-life: 12 months
Specificity: This assay has high sensitivity and excellent specificity for detection of Matrix Metalloproteinase 9 (MMP9). No significant cross-reactivity or interference between Matrix Metalloproteinase 9 (MMP9) and analogues was observed.
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C; 8. Read RLU value immediately.
Test principle: The microplate provided in this kit has been pre-coated with an antibody specific to Matrix Metalloproteinase 9 (MMP9). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Matrix Metalloproteinase 9 (MMP9). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Matrix Metalloproteinase 9 (MMP9) level in the sample or standard.;
Research Area: Enzyme & Kinase;Tumor immunity;Infection immunity;Cardiovascular biology;Hepatology;
References Citing This Product: -