GeneBio Systems
Human Krueppel-like factor 15 (KLF15) ELISA Kit
Human Krueppel-like factor 15 (KLF15) ELISA Kit
SKU:AE36619HU
Couldn't load pickup availability
Size: 96T. Other sizes are also available.
Species Reactivity: Human (Homo sapiens)
UniProt: Q9UIH9
Abbreviation: KLF15
Alternative Names: DKFZp779M1320; KKLF; kidney-enriched Kruppel-like factor
Application: ELISA
Range: 0.156-10 ng/mL
Sensitivity: 0.068 ng/mL
Test principle: This assay employs a two-site sandwich ELISA to quantitate KLF15 in samples. An antibody specific for KLF15 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyKLF15 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for KLF15 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of KLF15 bound in the initial step. The color development is stopped and the intensity of the color is measured.
Product Overview: KLF15 protein is 84% identical to the rat Klf15 protein, contains 3 zinc finger motifs at its C terminus, N-terminal serine-rich stretches, and a central proline-rich segment. EMSA analysis confirmed that KLF15 and MAZ interact with the GA element of the CLCNKA promoter and showed that KLF15 binds with higher affinity and is a functional competitor of MAZ. Northern blot analysis revealed highest expression of a 2.5-kb KLF15 transcript in liver, followed by heart, skeletal muscle, and kidney. No expression was found in bone marrow or lymphoid tissues. KLF15 was also expressed in cardiac and skeletal muscle interstitial cells and in kidney inner medulla, glomeruli, and cortical interstitium. Immunofluorescence microscopy, however, demonstrated no colocalization of KLF15 with CLCNKA.
Stability: The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. The loss rate was determined by accelerated thermal degradation test. Keep the kit at 37°C for 4 and 7 days, and compare O.D.values of the kit kept at 37°C with that of at recommended temperature. (referring from China Biological Products Standard, which was calculated by the Arrhenius equation. For ELISA kit, 4 days storage at 37°C can be considered as 6 months at 2 - 8°C, which means 7 days at 37°C equaling 12 months at 2 - 8°C).
