Skip to product information
1 of 1

GeneBio Systems

FBLN3 ELISA kit (Human)

FBLN3 ELISA kit (Human)

SKU:SEF422Hu

Regular price €996,95 EUR
Regular price Sale price €996,95 EUR
Sale Sold out
Shipping calculated at checkout.

Size: 96Tests

# of Times Cited in literature: 17

Prepare Time: 1-3 days(please inquire for mutiple units)

Target Name: FBLN3

Target Full Name: Fibulin 3

Alternative Names: EFEMP1; DHRD; DRAD; FBNL; MLVT; MTLV; S1-5; EGF-Containing Fibulin-Like Extracellular Matrix Protein 1; Fibrillin-Like; Extracellular protein S1-5

Target Species: Human

Uniprot: Q12805

Gene ID: 2202

Featured Series: SE kit

Featured Series Function: Detects protein (regular version)

Specificity: Reactive with Human FBLN3 / Fibulin 3

Method: Colormetric

Detection principle: Double-antibody Sandwich

Detection range: 1.56-100ng/mL

Sensitivity: 0.64ng/mL

Assay Time: 3h

Sample Size: 100uL

Recommended/Predicted Sample Types: Serum, Plasma, Urine and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibulin 3 (FBLN3) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibulin 3 (FBLN3) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Fibulin 3 (FBLN3). No significant cross-reactivity or interference between Fibulin 3 (FBLN3) and analogues was observed.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Fibulin 3 (FBLN3). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Fibulin 3 (FBLN3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Fibulin 3 (FBLN3), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Fibulin 3 (FBLN3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Research Area: Metabolic pathway;

References Citing This Product: Fibulin-3 as a Blood and Effusion Biomarker for Pleural Mesothelioma

YKL-40 and mesothelin in the blood of patients with malignant mesothelioma, lung cancer and asbestosis.

Role of fibulin-3 in lung cancer: In vivo and in vitro analyses

Discovery of new biomarkers for malignant mesothelioma

DIAGNOSIS OF CELL PROLIFERATIVE DISEASES

Comparison of fibulin-3 and mesothelin as markers in malignant mesothelioma

Value of plasma and pleural effusion fibulin-3 levels in the diagnosis of malignant pleural mesothelioma effusions

Fibulin-3 as a biomarker of response to treatment in malignant mesothelioma

Fibulin-3 levels in malignant pleural mesothelioma are associated with prognosis but not diagnosis

Plasma Biomarker Enrichment of Clinical Prognostic Indices in Malignant Pleural Mesothelioma.

Diagnostic and Prognostic Biomarkers in the Rational Assessment of Mesothelioma (DIAPHRAGM) study: protocol of a prospective, multicentre, observational study

HMGB1 and its hyperacetylated isoform are sensitive and specific serum biomarkers to detect asbestos exposure and to identify mesothelioma patients

Diagnostic and Prognostic Biomarkers in the Rational Assessment of Mesothelioma (DIAPHRAGM) study: protocol of a prospective, multicentre, observational …

Comparison of the Diagnostic Performance of Fibulin-3 and Mesothelin in Patients with Pleural Effusions from Malignant Mesothelioma.

A Novel Panel of Serum Biomarkers for MPM Diagnosis.

Association of fibulin-3 concentrations with the presence and severity of knee osteoarthritis: A cross-sectional study

Plasma Fibulin-3 as a Potential Biomarker for Patients with Asbestos-Related Diseases in the Han Population

Placental protein 14 as a potential biomarker for diagnosis of preterm premature rupture of membranes

The matrix protein Fibulin-3 promotes KISS1R induced triple negative breast cancer cell invasion

Fibulin-3 and other cartilage metabolism biomarkers in relationship to calprotectin (MRP8/14) and disease activity in rheumatoid arthritis patients treated with …

Prediction of pneumoconiosis by serum and urinary biomarkers in workers exposed to asbestos-contaminated minerals

View full details