TIMP3 CLIA kit (Human)
TIMP3 CLIA kit (Human)
SKU:SCA129Hu
Couldn't load pickup availability
Size: 96Tests
# of Times Cited in literature: -
Prepare Time: 2-7 days(please inquire for mutiple units)
Target Name: TIMP3
Target Full Name: Tissue Inhibitors Of Metalloproteinase 3
Alternative Names: SFD; TIMP Metallopeptidase Inhibitor 3; Metallopeptidase Inhibitor 3; Sorsby Fundus Dystrophy; Pseudoinflammatory
Target Species: Human
Uniprot: P35625
Gene ID: 7078
Featured Series: SE kit
Featured Series Function: Detects protein (regular version)
Specificity: Reactive with Human TIMP3 / Tissue Inhibitors Of Metalloproteinase 3
Method: Chemiluminescence
Detection principle: Double-antibody Sandwich
Detection range: 0.08-60ng/mL
Sensitivity: 0.03ng/mL
Assay Time: 2h, 40min
Sample Size: 100uL
Recommended/Predicted Sample Types: Serum, Plasma, Tissue Homogenates and other Biological Fluids
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tissue Inhibitors Of Metalloproteinase 3 (TIMP3) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tissue Inhibitors Of Metalloproteinase 3 (TIMP3) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Shelf-life: 12 months
Specificity: This assay has high sensitivity and excellent specificity for detection of Tissue Inhibitors Of Metalloproteinase 3 (TIMP3). No significant cross-reactivity or interference between Tissue Inhibitors Of Metalloproteinase 3 (TIMP3) and analogues was observed.
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C; 8. Read RLU value immediately.
Test principle: The microplate provided in this kit has been pre-coated with an antibody specific to Tissue Inhibitors Of Metalloproteinase 3 (TIMP3). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Tissue Inhibitors Of Metalloproteinase 3 (TIMP3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Tissue Inhibitors Of Metalloproteinase 3 (TIMP3) level in the sample or standard.;
Research Area: Tumor immunity;Cardiovascular biology;
References Citing This Product: -