Skip to product information
1 of 1

GeneBio Systems

SDC1 ELISA kit (Human)

SDC1 ELISA kit (Human)

SKU:SEB966Hu

Regular price €947,95 EUR
Regular price Sale price €947,95 EUR
Sale Sold out
Shipping calculated at checkout.

Size: 96Tests

# of Times Cited in literature: 11

Prepare Time: 1-3 days(please inquire for mutiple units)

Target Name: SDC1

Target Full Name: Syndecan 1

Alternative Names: CD138; SDC; SYND1; Syndecan Proteoglycan 1

Target Species: Human

Uniprot: P18827

Gene ID: 6382

Featured Series: SE kit

Featured Series Function: Detects protein (regular version)

Specificity: Reactive with Human SDC1 / Syndecan 1

Method: Colormetric

Detection principle: Double-antibody Sandwich

Detection range: 1.56-100ng/mL

Sensitivity: 0.57ng/mL

Assay Time: 3h

Sample Size: 100uL

Recommended/Predicted Sample Types: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Syndecan 1 (SDC1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Syndecan 1 (SDC1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Syndecan 1 (SDC1). No significant cross-reactivity or interference between Syndecan 1 (SDC1) and analogues was observed.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Syndecan 1 (SDC1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Syndecan 1 (SDC1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Syndecan 1 (SDC1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Syndecan 1 (SDC1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Research Area: Tumor immunity;Infection immunity;Immunodeficiency;

References Citing This Product: Endothelial glycocalyx layer shedding following lung resection

Volume kinetics of Ringer's lactate solution in acute inflammatory disease

Postoperative microcirculatory perfusion and endothelial glycocalyx shedding following cardiac surgery with cardiopulmonary bypass

Microvascular alterations during cardiac surgery using a heparin or phosphorylcholine coated circuit

Increased syndecan-1 and glypican-3 predict poor perinatal outcome and treatment resistance in intrahepatic cholestasis: Syndecan-1, glypican-3 and ICP

Heparin Binding Protein and Endothelial Glycocalyx Markers in Severe COVID-19–A Prospective Observational Cohort Study

The effect of pre-operative methylprednisolone on postoperative delirium in elderly patients undergoing gastrointestinal surgery: a randomized, double-blind, placebo …

View full details