Skip to product information
1 of 1

GeneBio Systems

SCNN1g ELISA kit (Human)

SCNN1g ELISA kit (Human)

SKU:SED335Hu

Regular price €996,95 EUR
Regular price Sale price €996,95 EUR
Sale Sold out
Shipping calculated at checkout.

Size: 96Tests

# of Times Cited in literature: -

Prepare Time: 2-7 days(please inquire for mutiple units)

Target Name: SCNN1g

Target Full Name: Amiloride Sensitive Sodium Channel Subunit Gamma

Alternative Names: ENaCg; ENaCgamma; PHA1; SCNEG; Sodium Channel,Nonvoltage-Gated 1,Alpha; Epithelial Na(+) channel subunit gamma; Nonvoltage-gated sodium channel 1 subunit gamma

Target Species: Human

Uniprot: P51170

Gene ID: 6340

Featured Series: SE kit

Featured Series Function: Detects protein (regular version)

Specificity: Reactive with Human SCNN1g / Amiloride Sensitive Sodium Channel Subunit Gamma

Method: Colormetric

Detection principle: Double-antibody Sandwich

Detection range: 0.312-20ng/mL

Sensitivity: 0.112ng/mL

Assay Time: 3h

Sample Size: 100uL

Recommended/Predicted Sample Types: Tissue Homogenates, Cell Lysates and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Amiloride Sensitive Sodium Channel Subunit Gamma (SCNN1g) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Amiloride Sensitive Sodium Channel Subunit Gamma (SCNN1g) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Amiloride Sensitive Sodium Channel Subunit Gamma (SCNN1g). No significant cross-reactivity or interference between Amiloride Sensitive Sodium Channel Subunit Gamma (SCNN1g) and analogues was observed.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Amiloride Sensitive Sodium Channel Subunit Gamma (SCNN1g). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Amiloride Sensitive Sodium Channel Subunit Gamma (SCNN1g). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Amiloride Sensitive Sodium Channel Subunit Gamma (SCNN1g), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Amiloride Sensitive Sodium Channel Subunit Gamma (SCNN1g) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Research Area: Signal transduction;

References Citing This Product: -

View full details