GeneBio Systems
LAMC2 ELISA kit (Human)
LAMC2 ELISA kit (Human)
SKU:SEC083Hu
Couldn't load pickup availability
Size: 96Tests
# of Times Cited in literature: 5
Prepare Time: 1-3 days(please inquire for mutiple units)
Target Name: LAMC2
Target Full Name: Laminin Gamma 2
Alternative Names: B2T; EBR2; EBR2A; LAMB2T; LAMNB2; Kalinin/nicein/epiligrin 100 kDa subunit; Cell-scattering factor 140 kDa subunit; Ladsin 140 kDa; Large adhesive scatter factor 140 kDa
Target Species: Human
Uniprot: Q13753
Gene ID: 3918
Featured Series: SE kit
Featured Series Function: Detects protein (regular version)
Specificity: Reactive with Human LAMC2 / Laminin Gamma 2
Method: Colormetric
Detection principle: Double-antibody Sandwich
Detection range: 15.6-1,000pg/mL
Sensitivity: 6.2pg/mL
Assay Time: 3h
Sample Size: 100uL
Recommended/Predicted Sample Types: Serum, Plasma, Tissue Homogenates and other Biological Fluids
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Reproducibility test menthod: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Laminin Gamma 2 (LAMC2) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Laminin Gamma 2 (LAMC2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Shelf-life: 12 months
Specificity: This assay has high sensitivity and excellent specificity for detection of Laminin Gamma 2 (LAMC2). No significant cross-reactivity or interference between Laminin Gamma 2 (LAMC2) and analogues was observed.
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Laminin Gamma 2 (LAMC2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Laminin Gamma 2 (LAMC2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Laminin Gamma 2 (LAMC2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Laminin Gamma 2 (LAMC2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Research Area: Developmental science;
References Citing This Product: LAMC2: A promising new pancreatic cancer biomarker identified by proteomic analysis of pancreatic adenocarcinoma tissues
Validation of Biomarkers That Complement CA19.9 in Detecting Early Pancreatic Cancer
Serum LAMC2 enhances the prognostic value of a multi-parametric panel in non-small cell lung cancer
Prognostic significance of circulating laminin gamma2 for early-stage non-small-cell lung cancer
PRETERM BIRTH PREDICTION IN ASYMPTOMATIC WOMEN AT MID-GESTATION USING A PANEL OF NOVEL PROTEIN BIOMARKERS: The Prediction of PreTerm …
Biomarkers of Preterm Birth