{"product_id":"esm1-elisa-kit-for-human","title":"ESM1 ELISA kit (Human)","description":"\u003cp\u003e\u003cb\u003eSize\u003c\/b\u003e: 96Tests\u003c\/p\u003e\u003cp\u003e\u003cb\u003e# of Times Cited in literature\u003c\/b\u003e: 13\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePrepare Time\u003c\/b\u003e: 1-3 days(please inquire for mutiple units)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Name\u003c\/b\u003e: ESM1\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Full Name\u003c\/b\u003e: Endothelial Cell Specific Molecule 1\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAlternative Names\u003c\/b\u003e: Endocan\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Species\u003c\/b\u003e: Human\u003c\/p\u003e\u003cp\u003e\u003cb\u003eUniprot\u003c\/b\u003e: Q9NQ30\u003c\/p\u003e\u003cp\u003e\u003cb\u003eGene ID\u003c\/b\u003e: 11082\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatured Series\u003c\/b\u003e: SE kit\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatured Series Function\u003c\/b\u003e: Detects protein (regular version)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecificity\u003c\/b\u003e: Reactive with Human ESM1 \/ Endothelial Cell Specific Molecule 1\u003c\/p\u003e\u003cp\u003e\u003cb\u003eMethod\u003c\/b\u003e: Colormetric\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDetection principle\u003c\/b\u003e: Double-antibody Sandwich\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDetection\nrange\u003c\/b\u003e: 0.156-10ng\/mL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSensitivity\u003c\/b\u003e: 0.065ng\/mL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay Time\u003c\/b\u003e: 3h\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSample Size\u003c\/b\u003e: 100uL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eRecommended\/Predicted\nSample Types\u003c\/b\u003e: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay Precision\u003c\/b\u003e: Intra-Assay: CV\u0026lt;10%, Inter-Assay: CV\u0026lt;12%\u003c\/p\u003e\u003cp\u003e\u003cb\u003eReproducibility test menthod\u003c\/b\u003e: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Endothelial Cell Specific Molecule 1 (ESM1) were tested 20 times on one plate, respectively.\nInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Endothelial Cell Specific Molecule 1 (ESM1) were tested on 3 different plates, 8 replicates in each plate.\nCV(%) = SD\/meanX100\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStorage\u003c\/b\u003e: 4°C for 1 month\/ -20°C for long-term(One year within shelf life)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eShelf-life\u003c\/b\u003e: 12 months\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecificity\u003c\/b\u003e: This assay has high sensitivity and excellent specificity for detection of Endothelial Cell Specific Molecule 1 (ESM1).\nNo significant cross-reactivity or interference between Endothelial Cell Specific Molecule 1 (ESM1) and analogues was observed.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStability\u003c\/b\u003e: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\nTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay procedure summary\u003c\/b\u003e: 1. Prepare all reagents, samples and standards;\n2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;\n3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;\n4. Aspirate and wash 3 times;\n5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;\n6. Aspirate and wash 5 times;\n7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;\n8. Add 50µL Stop Solution. Read at 450nm immediately.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTest principle\u003c\/b\u003e: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Endothelial Cell Specific Molecule 1 (ESM1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Endothelial Cell Specific Molecule 1 (ESM1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Endothelial Cell Specific Molecule 1 (ESM1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Endothelial Cell Specific Molecule 1 (ESM1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eResearch Area\u003c\/b\u003e: Metabolic pathway;Tumor immunity;Infection immunity;Cardiovascular biology;\u003c\/p\u003e\u003cp\u003e\u003cb\u003eReferences Citing This Product\u003c\/b\u003e: \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/22608803\"\u003eDetection on dynamic changes of endothelial cell specific molecule-1 in acute rejection after renal transplantation\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/24769132\"\u003eEndocan is useful biomarker of survival and severity in sepsis.\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/25211383\"\u003eEndocan, a putative endothelial cell marker, is elevated in preeclampsia, decreased in acute pyelonephritis, and unchanged in other obstetrical syndromes\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/24769132\"\u003eEndocan is useful biomarker of survival and severity in sepsis\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26614790\"\u003eEndocan Levels and Subclinical Atherosclerosis in Patients With Systemic Lupus Erythematosus\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.termedia.pl\/Journal\/-102\/pdf-28860-10?filename=assessment%20(1).pdf\"\u003eAssessment of subclinical cardiac damage in chronic plaque psoriasis patients: a case control study\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28514746\"\u003eDiagnostic and prognostic values of endothelial-cell-specific molecule-1 with malignant pleural effusions in patients with non-small cell lung cancer\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.researchgate.net\/publication\/316105432\"\u003eChanges in Endocan Levels and Blood Coagulation in HIV Infection\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/30054863\"\u003eIs the plasma endocan level a reliable predictor for the severity of erectile dysfunction?\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/benthamopen.com\/FULLTEXT\/TORJ-12-189\"\u003eSerum Level of Endothelial Cell-Specific Molecule-1 (ESM-1) as a New Potential Biomarker for Rheumatoid Arthritis Disease Activity\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.futuremedicine.com\/doi\/abs\/10.2217\/bmm-2018-0282\"\u003eEndothelial biomarkers in the light of new sepsis definition\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.spandidos-publications.com\/10.3892\/etm.2019.7485\"\u003eRisk stratification and prognostic evaluation of endothelial cell‑specific molecule1, von Willebrand factor, and a disintegrin‑like and metalloprotease with …\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31655533\/\"\u003eA novel marker relationship between carotid intima–media thickness and disease activity score-28 in patients with rheumatoid arthritis: human endothelial cell …\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32364003\/\"\u003eRole of Ascitic Endocan Levels in the Diagnosis of Spontaneous Bacterial Peritonitis in Decompensated Cirrhosis\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/34109715\"\u003eComparison of the maternal serum endocan levels in preterm premature rupture of membrane and normal pregnancy\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/dergipark.org.tr\/en\/pub\/tjcl\/issue\/59068\/720147\"\u003eThe relationship between serum endocan levels with the presence of contrast-induced nephropathy in patients undergoing coronary angiography\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e","brand":"GeneBio Systems","offers":[{"title":"Default Title","offer_id":48696704761956,"sku":"SEC463Hu","price":1470.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/8588\/9636\/files\/no_image_default_image-jpeg_1209be39-23ff-4861-b851-cc7f959ce0be.jpg?v=1783134763","url":"https:\/\/www.genebiosystems.com\/products\/esm1-elisa-kit-for-human","provider":"GeneBio ","version":"1.0","type":"link"}