{"product_id":"il31-clia-kit-for-mouse","title":"IL31 CLIA kit (Mouse)","description":"\u003cp\u003e\u003cb\u003eSize\u003c\/b\u003e: 96Tests\u003c\/p\u003e\u003cp\u003e\u003cb\u003e# of Times Cited in literature\u003c\/b\u003e: -\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePrepare Time\u003c\/b\u003e: 2-7 days(please inquire for mutiple units)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Name\u003c\/b\u003e: IL31\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Full Name\u003c\/b\u003e: Interleukin 31\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAlternative Names\u003c\/b\u003e: -\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Species\u003c\/b\u003e: Mouse\u003c\/p\u003e\u003cp\u003e\u003cb\u003eUniprot\u003c\/b\u003e: Q6EAL8\u003c\/p\u003e\u003cp\u003e\u003cb\u003eGene ID\u003c\/b\u003e: 76399\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatured Series\u003c\/b\u003e: SE kit\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatured Series Function\u003c\/b\u003e: Detects protein (regular version)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecificity\u003c\/b\u003e: Reactive with Mouse IL31 \/ Interleukin 31\u003c\/p\u003e\u003cp\u003e\u003cb\u003eMethod\u003c\/b\u003e: Chemiluminescence\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDetection principle\u003c\/b\u003e: Double-antibody Sandwich\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDetection\nrange\u003c\/b\u003e: 0.55-400pg\/mL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSensitivity\u003c\/b\u003e: 0.19pg\/mL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay Time\u003c\/b\u003e: 2h, 40min\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSample Size\u003c\/b\u003e: 100uL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eRecommended\/Predicted\nSample Types\u003c\/b\u003e: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay Precision\u003c\/b\u003e: Intra-Assay: CV\u0026lt;10%, Inter-Assay: CV\u0026lt;12%\u003c\/p\u003e\u003cp\u003e\u003cb\u003eReproducibility test menthod\u003c\/b\u003e: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 31 (IL31) were tested 20 times on one plate, respectively.\nInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 31 (IL31) were tested on 3 different plates, 8 replicates in each plate.\nCV(%) = SD\/meanX100\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStorage\u003c\/b\u003e: 4°C for 1 month\/ -20°C for long-term(One year within shelf life)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eShelf-life\u003c\/b\u003e: 12 months\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecificity\u003c\/b\u003e: This assay has high sensitivity and excellent specificity for detection of Interleukin 31 (IL31).\nNo significant cross-reactivity or interference between Interleukin 31 (IL31) and analogues was observed.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStability\u003c\/b\u003e: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\nTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay procedure summary\u003c\/b\u003e: 1. Prepare all reagents, samples and standards;\n2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;\n3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;\n4. Aspirate and wash 3 times;\n5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;\n6. Aspirate and wash 5 times;\n7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;\n8. Read RLU value immediately.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTest principle\u003c\/b\u003e: The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 31 (IL31). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 31 (IL31). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 31 (IL31) level in the sample or standard.;\u003c\/p\u003e\u003cp\u003e\u003cb\u003eResearch Area\u003c\/b\u003e: Cytokine;Tumor immunity;Infection immunity;Dermatology;\u003c\/p\u003e\u003cp\u003e\u003cb\u003eReferences Citing This Product\u003c\/b\u003e: -\u003c\/p\u003e","brand":"GeneBio Systems","offers":[{"title":"Default Title","offer_id":48697719455844,"sku":"SCB179Mu","price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/8588\/9636\/files\/no_image_default_image-jpeg_284c96bb-67fc-4708-b0c8-54d350a6e225.jpg?v=1783148733","url":"https:\/\/www.genebiosystems.com\/en-us\/products\/il31-clia-kit-for-mouse","provider":"GeneBio ","version":"1.0","type":"link"}