{"product_id":"cypa-elisa-kit-for-human","title":"CYPA ELISA kit (Human)","description":"\u003cp\u003e\u003cb\u003eSize\u003c\/b\u003e: 96Tests\u003c\/p\u003e\u003cp\u003e\u003cb\u003e# of Times Cited in literature\u003c\/b\u003e: 15\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePrepare Time\u003c\/b\u003e: 1-3 days(please inquire for mutiple units)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Name\u003c\/b\u003e: CYPA\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Full Name\u003c\/b\u003e: Cyclophilin A\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAlternative Names\u003c\/b\u003e: PPIA; CyP-A; CYPH; Peptidylprolyl Isomerase A; Peptidyl-Prolyl Isomerase A; Peptidyl-prolyl cis-trans isomerase A; Cyclosporin A-binding protein\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Species\u003c\/b\u003e: Human\u003c\/p\u003e\u003cp\u003e\u003cb\u003eUniprot\u003c\/b\u003e: P62937\u003c\/p\u003e\u003cp\u003e\u003cb\u003eGene ID\u003c\/b\u003e: 5478\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatured Series\u003c\/b\u003e: SE kit\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatured Series Function\u003c\/b\u003e: Detects protein (regular version)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecificity\u003c\/b\u003e: Reactive with Human CYPA \/ Cyclophilin A\u003c\/p\u003e\u003cp\u003e\u003cb\u003eMethod\u003c\/b\u003e: Colormetric\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDetection principle\u003c\/b\u003e: Double-antibody Sandwich\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDetection\nrange\u003c\/b\u003e: 1.25-80ng\/mL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSensitivity\u003c\/b\u003e: 0.49ng\/mL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay Time\u003c\/b\u003e: 3h\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSample Size\u003c\/b\u003e: 100uL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eRecommended\/Predicted\nSample Types\u003c\/b\u003e: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay Precision\u003c\/b\u003e: Intra-Assay: CV\u0026lt;10%, Inter-Assay: CV\u0026lt;12%\u003c\/p\u003e\u003cp\u003e\u003cb\u003eReproducibility test menthod\u003c\/b\u003e: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cyclophilin A (CYPA) were tested 20 times on one plate, respectively.\nInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cyclophilin A (CYPA) were tested on 3 different plates, 8 replicates in each plate.\nCV(%) = SD\/meanX100\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStorage\u003c\/b\u003e: 4°C for 1 month\/ -20°C for long-term(One year within shelf life)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eShelf-life\u003c\/b\u003e: 12 months\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecificity\u003c\/b\u003e: This assay has high sensitivity and excellent specificity for detection of Cyclophilin A (CYPA).\nNo significant cross-reactivity or interference between Cyclophilin A (CYPA) and analogues was observed.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStability\u003c\/b\u003e: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\nTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay procedure summary\u003c\/b\u003e: 1. Prepare all reagents, samples and standards;\n2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;\n3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;\n4. Aspirate and wash 3 times;\n5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;\n6. Aspirate and wash 5 times;\n7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;\n8. Add 50µL Stop Solution. Read at 450nm immediately.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTest principle\u003c\/b\u003e: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Cyclophilin A (CYPA). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Cyclophilin A (CYPA). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Cyclophilin A (CYPA), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Cyclophilin A (CYPA) in the samples is then determined by comparing the O.D. of the samples to the standard curve.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eResearch Area\u003c\/b\u003e: Tumor immunity;Infection immunity;\u003c\/p\u003e\u003cp\u003e\u003cb\u003eReferences Citing This Product\u003c\/b\u003e: \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/19758589\"\u003eEMMPRIN and its ligand cyclophilin A regulate MT1-MMP, MMP-9 and M-CSF during foam cell formation\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/24164594\"\u003eCyclophilin-A: a novel biomarker for untreated male essential hypertension\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/24502618\"\u003ePlasma level of cyclophilin A is increased in patients with type 2 diabetes mellitus and suggests presence of vascular disease\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/25552928\"\u003eDecrease in Plasma Cyclophilin A Concentration at 1 Month after Myocardial Infarction Predicts Better Left Ventricular Performance and Synchronicity at 6 Months: A Pilot Study in Patients with ST Elevation Myocardial Infarction\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26426668%20\"\u003eCyclophilin A in Ruptured Intracranial Aneurysm\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26702934\"\u003ePPIA rs6850: A\u0026gt; G single-nucleotide polymorphism is associated with raised plasma cyclophilin A levels in patients with coronary artery disease\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26496315\"\u003eUrinary Cyclophilin A as a New Marker for Diabetic Nephropathy: A Cross-Sectional Analysis of Diabetes Mellitus\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27809851\"\u003eCyclophilin A enhances macrophage differentiation and lipid uptake in high glucose conditions: a cellular mechanism for accelerated macro vascular disease in diabetes mellitus.\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/29382697\"\u003eMetformin attenuates effects of cyclophilin A on macrophages, reduces lipid uptake and secretion of cytokines by repressing decreased AMPK activity\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.tandfonline.com\/doi\/full\/10.1080\/10715762.2018.1523545\"\u003eCyclophilin A and CD147 associate with progression of diabetic nephropathy\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31670477\/\"\u003eAssociation of cyclophilin A level and pulse pressure in predicting recurrence of cerebral infarction\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31936351\/\"\u003eCyclophilin A\/EMMPRIN Axis Is Involved in Pro-Fibrotic Processes Associated with Thoracic Aortic Aneurysm of Marfan Syndrome Patients\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/24030206\/\"\u003eAPPENDIX A: Relationship between cyclophilin A levels and matrix metalloproteinase-9 activity in cerebrospinal fluid of cognitively normal apolipoprotein E4 carriers …\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.mmj.eg.net\/article.asp?issn=1110-2098year=2019volume=32issue=3spage=996epage=1003aulast=El-Saeed\"\u003eUrinary podocalyxin and cyclophilin A: markers for early detection of type 2 diabetic nephropathy\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e","brand":"GeneBio Systems","offers":[{"title":"Default Title","offer_id":48696731238500,"sku":"SEA979Hu","price":1093.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/8588\/9636\/files\/no_image_default_image-jpeg_dbec819a-1211-43c8-8f57-0a41455cb863.jpg?v=1783135458","url":"https:\/\/www.genebiosystems.com\/en-us\/products\/cypa-elisa-kit-for-human","provider":"GeneBio ","version":"1.0","type":"link"}