{"product_id":"anxa2-elisa-kit-for-human","title":"ANXA2 ELISA kit (Human)","description":"\u003cp\u003e\u003cb\u003eSize\u003c\/b\u003e: 96Tests\u003c\/p\u003e\u003cp\u003e\u003cb\u003e# of Times Cited in literature\u003c\/b\u003e: 19\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePrepare Time\u003c\/b\u003e: 1-3 days(please inquire for mutiple units)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Name\u003c\/b\u003e: ANXA2\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Full Name\u003c\/b\u003e: Annexin A2\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAlternative Names\u003c\/b\u003e: ANX-A2; ANX2L4; CAL1H; LIP2; LPC2; LPC2D; P36; PAP-IV; Protein I; Chromobindin-8; Calpactin-1 heavy chain; Lipocortin II; Placental anticoagulant protein IV\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTarget Species\u003c\/b\u003e: Human\u003c\/p\u003e\u003cp\u003e\u003cb\u003eUniprot\u003c\/b\u003e: P07355\u003c\/p\u003e\u003cp\u003e\u003cb\u003eGene ID\u003c\/b\u003e: 302\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatured Series\u003c\/b\u003e: SE kit\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatured Series Function\u003c\/b\u003e: Detects protein (regular version)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecificity\u003c\/b\u003e: Reactive with Human ANXA2 \/ Annexin A2\u003c\/p\u003e\u003cp\u003e\u003cb\u003eMethod\u003c\/b\u003e: Colormetric\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDetection principle\u003c\/b\u003e: Double-antibody Sandwich\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDetection\nrange\u003c\/b\u003e: 0.156-10ng\/mL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSensitivity\u003c\/b\u003e: 0.054ng\/mL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay Time\u003c\/b\u003e: 3h\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSample Size\u003c\/b\u003e: 100uL\u003c\/p\u003e\u003cp\u003e\u003cb\u003eRecommended\/Predicted\nSample Types\u003c\/b\u003e: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay Precision\u003c\/b\u003e: Intra-Assay: CV\u0026lt;10%, Inter-Assay: CV\u0026lt;12%\u003c\/p\u003e\u003cp\u003e\u003cb\u003eReproducibility test menthod\u003c\/b\u003e: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Annexin A2 (ANXA2) were tested 20 times on one plate, respectively.\nInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Annexin A2 (ANXA2) were tested on 3 different plates, 8 replicates in each plate.\nCV(%) = SD\/meanX100\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStorage\u003c\/b\u003e: 4°C for 1 month\/ -20°C for long-term(One year within shelf life)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eShelf-life\u003c\/b\u003e: 12 months\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecificity\u003c\/b\u003e: This assay has high sensitivity and excellent specificity for detection of Annexin A2 (ANXA2).\nNo significant cross-reactivity or interference between Annexin A2 (ANXA2) and analogues was observed.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStability\u003c\/b\u003e: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\nTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAssay procedure summary\u003c\/b\u003e: 1. Prepare all reagents, samples and standards;\n2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;\n3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;\n4. Aspirate and wash 3 times;\n5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;\n6. Aspirate and wash 5 times;\n7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;\n8. Add 50µL Stop Solution. Read at 450nm immediately.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTest principle\u003c\/b\u003e: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Annexin A2 (ANXA2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Annexin A2 (ANXA2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Annexin A2 (ANXA2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Annexin A2 (ANXA2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eResearch Area\u003c\/b\u003e: Signal transduction;Tumor immunity;Bone metabolism;\u003c\/p\u003e\u003cp\u003e\u003cb\u003eReferences Citing This Product\u003c\/b\u003e: \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/20225235\"\u003eSubcellular proteome analysis unraveled annexin A2 related to immune liver fibrosis\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3491596\/\"\u003eExpression characteristics and diagnostic value of annexin A2 in hepatocellular carcinoma\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3742823\/\"\u003eAnnexin A2 is not a good biomarker for hepatocellular carcinoma in cirrhosis\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ghrnet.org\/index.php\/joghr\/article\/view\/482\"\u003eAnnexin A2 Versus Afp as An Efficient Diagnostic Serum Marker for Hepatocellular Carcinoma\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/24853056\"\u003eSerum annexin A2 levels in acute brucellosis and brucellar spondylodiscitis\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/25661364\"\u003eCirculating annexin A2 as a biomarker in gastric cancer patients: Correlation with clinical variables\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26587036%20\"\u003eSerum Levels of Annexin A2 as a Candidate Biomarker for Hepatic Fibrosis in Patients With Chronic Hepatitis B\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26109000\"\u003eUp-regulation of annexin A2 expression predicates advanced clinicopathological features and poor prognosis in hepatocellular carcinoma\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/%2025661364%20\"\u003eCirculating\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/%2026189841\"\u003eEvaluation of annexin A2 and as potential biomarkers for hepatocellular carcinoma\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26081791\"\u003eStairs instead of elevators at the workplace decreases PCSK9 levels in a healthy population\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27889534\"\u003eSerum Annexin A2 Level Is Associated With Diagnosis and Prognosis in Patients With OralSquamous Cell Carcinoma.\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28501283\"\u003eAssessment of annexin A5 and annexin A2 levels as biomarkers for pre-eclampsia: A pilot study.\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28181408\"\u003eEpigallocatechin gallate induces an up-regulation of LDL receptor accompanied by a reduction of PCSK9 via the annexin A2-independent pathway in HepG2 cells.\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/link.springer.com\/article\/10.1007\/s00404-019-05205-w\"\u003eExpression of annexin A2 in adenomyosis and dysmenorrhea\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31842290\/\"\u003eExtracellular Vesicles-Based Biomarkers Represent a Promising Liquid Biopsy in Endometrial Cancer\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.freepatentsonline.com\/y2020\/0309780.html\"\u003ePLASMA BIOMARKER FOR OVARIAN CANCER\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/33406648\"\u003eDiagnostic Value of Plasma Annexin A2 in Early-Stage High-Grade Serous Ovarian Cancer. Diagnostics 2021, 11, 69\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e\u003ca href=\"https:\/\/cyberleninka.ru\/article\/n\/search-for-effective-serum-tumor-markers-for-early-diagnosis-of-hepatocellular-carcinoma-associated-with-hepatitis-c\"\u003eSearch for Effective Serum Tumor Markers for Early Diagnosis of Hepatocellular Carcinoma Associated with Hepatitis C\u003c\/a\u003e\u003cp\u003e \u003c\/p\u003e","brand":"GeneBio Systems","offers":[{"title":"Default Title","offer_id":48696705777764,"sku":"SEB944Hu","price":812.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/8588\/9636\/files\/no_image_default_image-jpeg_465b21b0-169a-4cf8-94aa-9dc6868e35e2.jpg?v=1783134802","url":"https:\/\/www.genebiosystems.com\/en-gb\/products\/anxa2-elisa-kit-for-human","provider":"GeneBio ","version":"1.0","type":"link"}